Collect

Avoid Timeouts When Building a Syniti Data Replication Target Connection

When building a target connection to Syniti Data Replication, each package built will stop and start the Data Replicator Service in Syniti Data Replication automatically (depending on a parameter setting in Common).

At a high level, to avoid the timeout and processing issues inherent with multiple stops and starts:

  1. Disable the Start Replicator parameter setting in Common.
  2. Stop the Syniti Data Replication Data Replicator service manually.
  3. Build target connections in Collect.
  4. Start the Syniti Data Replication Data Replicator service manually.
  5. Enable the Start Replicator parameter setting in Common.

 

Step one: To disable the Syniti Data Replication setting in Common:

  1. Select Configuration > Modules > Parameters – Collect in the Navigation pane.
  2. Select the DBMoto Settings tab.
  3. Click Edit.

    View the field descriptions for the Parameters – Collect page’s DBMoto Settings tab

  4. Click the Start Replicator check box to disable it.

    NOTE: When this check box is disabled, the Data Replicator must be stopped and started manually.

  5. Click Save.

 

Step two: Stop the Syniti Data Replication service manually on the Syniti Data Replication server. Stop the service from the Syniti Data Replication Service Monitor icon in the Windows Notification Area or from Control Panel > Administrative Tools > Services.

NOTE: Only one Data Replicator service is used per DSP® instance. When the service is stopped, it is stopped for all tables across all targets.

 

Step three: Build all target connections in Collect. Refer to Register Targets for more information.

 

Step four: Start the Syniti Data Replication service manually on the Syniti Data Replication server. Start the service from the Syniti Data Replication Service Monitor icon in the Windows Notification Area or from Control Panel > Administrative Tools > Services.

 

Step five: To enable the Syniti Data Replication setting in Common:

  1. Select Configuration > Modules > Parameters – Collect in the Navigation pane.
  2. Select the DBMoto Settings tab.
  3. Click Edit.

    View the field descriptions for the Parameters – Collect page’s DBMoto Settings tab

  4. Click the Start Replicator check box to enable it.

    NOTE: When this check box is enabled, the Data Replicator is stopped and started automatically.

  5. Click Save.